Case SR220, SR250, SV250, SV300 SkidSteer Service Manual (PIN NCM & NDM & NEM)

Price range: $37.00 through $38.00

What’s Included

Service Manual (PIN NCM & NDM) 2,091 Pages
Service Manual (PIN NEM) 2,061 Pages

Technical Details

Brand Case
Models Covered SR220, SR250, SV250, SV300 (Tier 4A)
Machine Type Skid Steer Loader
Documentation Service Manual
Serial Numbers SR220:
PIN NDM457559 and above
SR250:
PIN NCM442784 and above
PIN NEM443389 and above
SV250:
PIN NDM460776 and above
SV300:
PIN NCM445399 and above
PIN NEM469928 and above
Publication Numbers 47540695 (April 2014), 47674604
Language English
Format PDF
SKU: 258061 Category:
Guaranteed Safe Checkout

Table of Contents

  1. Contents
  2. Introduction
  3. Engine
  4. Front Axle System
  5. Rear Axle System
  6. Hydrostatic Drive
  7. Brakes and Controls
  8. Hydraulic Systems
  9. Frames and Ballasting
  10. Wheels
  11. Cab Climate Control
  12. Electrical System
  13. Front Loader and Bucket
  14. Platform, Cab, Bodywork and Decals
  15. Specials Tool Index

Manual Extract: Brake control solenoids – Overview

Solenoids work in much the same way as relays, except that the iron core is not fixed in place. As a result, the windings in the control circuit cause the iron core to move. In the starting system, for example, the movement of this core is used to send large amounts of current to the starter motor.

A solenoid is basically a winding around an iron core. In the Centre of the core there is a plunger which is free to move through the core. When an electrical current passes through the winding an electro-magnetic force is produced which causes the plunger to move through the core. If the current is switched off, the magnetic force is stopped and the plunger is returned by a spring.

The solenoid plunger may have different uses: the most common are moving a hydraulic spool or a mechanical lever.
The MOST COMMON FAULTS that can occur are:
• Short circuit winding: if a section of the winding allows the current to pass directly from positive (+) to negative (-) terminals without passing through the winding, this will cause the relevant circuit fuse to blow.
• Broken winding: causing an open circuit, it will not allow the current to pass through the winding, so the solenoid will not operate.
• Seized plunger (and/or connected components): the solenoid will only move the plunger if all components are free to move.

Model

SR220, SR250, SV250, SV300

Serial

PIN NDM457559 and above, PIN NCM442784 and above, PIN NDM460776 and above, PIN NCM445399 and above, PIN NEM443389 and above, PIN NEM469928 and above

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.